Viglen IX2000 Guida Utente Pagina 13

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 58
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 12
Viglen IX2000 Chassis User Guide
12
Jumper Settings on the SAS/SATA-2 Backplane:
SW1, Hardware Monitor Switch
Table 6: S1 Hardware Monitor Switch Configuration
No Function ON OFF
1 FAN1 Monitor Enabled *Disabled
2 FAN2 Monitor Enabled *Disabled
3 Alarm Temperature *65°C 55°C
* Default Settings
CN5, Front Panel Control Jumper
Table 7: CN5 Front Panel Control Jumper
Pin No. Function Pin No. Function
1 System Failure LED+ 2 N.A.
3 System Failure LED- 4 Alarm Mute Switch+
5 Key Pin 6 Alarm Mute Switch -
CN4, Failed HDD LED
Table 8: CN4 Failed HDD LED
Pin No. Function
1 Fail LED for HDD CN11
2 Fail LED for HDD CN21
3 Fail LED for HDD CN31
4 Fail LED for HDD CN41
Vedere la pagina 12